Selected publications

  • Feuerstein D, Manning A, Hashemi P, et al., , Journal of Cerebral Blood Flow and Metabolism Vol:30, ISSN:0271-678X, Pages:1343-1355.
  • Feuerstein D, Parker KH, Boutelle MG, 2009, , Analytical Chemistry, Vol:81, ISSN:0003-2700, Pages:4987-4994.
  • Hashemi P, Bhatia R, Nakamura H et al.,2009, , Journal of Cerebral Blood Flow and Metabolism, Vol:29, ISSN:0271-678X, Pages:166-175. Author web link.
  • Fabricius M, Fuhr S, Willumsen L etal., 2008, Association of seizures with cortical spreading depression and peri-infarct depolarisations in the acutely injured human brain, Clinical Neurophysiology, Vol:119, ISSN:1388-2457, Pages:1973-1984.
  • Caesar K, Hashemi P, Douhou A, et al., 008, , Journal of Physiology - London, Vol:586, ISSN:0022-3751, Pages:1337-1349.

Citation

BibTex format

@article{Corcoles:2011:10.1109/ICICI-BME.2011.6108659,
author = {Corcoles, EP and Deeba, S and Hanna, GB and Boutelle, MG and Darzi, A},
doi = {10.1109/ICICI-BME.2011.6108659},
journal = {Proceedings International Conference on Instrumentation Communication Information Technology and Biomedical Engineering 2011 Icici Bme 2011},
pages = {361--365},
title = {Measurements of bowel microdialysis recovery with an online biosensor system},
url = {http://dx.doi.org/10.1109/ICICI-BME.2011.6108659},
year = {2011}
}

RIS format (EndNote, RefMan)

TY  - JOUR
AB - Microdialysis is a sampling technique based on the passive diffusion of the molecules through a small segment of cylindrical hollow fiber membrane implanted within the tissue of study. Calibration of the microdialysis probe and the parameters that affect this calibration are essential, since recovery factors are never 100%. In vitro calibration methods are typically used to compare the concentration of the outlet with the concentration of the medium. In vivo quantification methods of microdialysis data monitoring depends on active and passive tissue effects, complicating the calibration methods further. In vitro and in vivo microdialysis calibration methods were performed in gastrointestinal tissue of animal models and intensive care patients. Results showed that the discrepancy between in vitro and in vivo calibration method is minimal. © 2011 IEEE.
AU - Corcoles,EP
AU - Deeba,S
AU - Hanna,GB
AU - Boutelle,MG
AU - Darzi,A
DO - 10.1109/ICICI-BME.2011.6108659
EP - 365
PY - 2011///
SP - 361
TI - Measurements of bowel microdialysis recovery with an online biosensor system
T2 - Proceedings International Conference on Instrumentation Communication Information Technology and Biomedical Engineering 2011 Icici Bme 2011
UR - http://dx.doi.org/10.1109/ICICI-BME.2011.6108659
ER -

Contact us


Department of Bioengineering
Room 3.14, Royal School of Mines Building
91桃色
London, SW7 2AZ

Tel: +44 (0)20 7594 5138
Email: m.boutelle@imperial.ac.uk

Map: We are location #12 on the map
Detailed instructions on how to find us on the campus